Load Bank LO-28/2500

Load bank LO-28/2500 is designed to apply current loads to 28 V d.c. outputs of any electronics power supply units available on the market, including ground power units (GPU).

The device allows to:

  • apply constant current loads
  • apply variable current load according to a pre-set program
  • measure voltage and load current with analogue indicators on the device’s control panel
  • connect external control-measuring devices to the measuring sockets

The unit provides comfort and functionality for daily maintenance and servicing of the controlled power supply units. Small weight and dimensions allow for easy loading on and attachment to the service vehicle, thus significantly increasing safety during transport.

Download PDF

Technical data

voltage
28 V d.c. +/-20%
load current
2500 A +/-20%
analogue voltmeter
class 1,5
analogue ammeter
class 1,5
exposures
300 A - 30 min
600 A - 20 min
Test - 6 exposures, 2500 A - 0 A
(35 secs +/- 10 %)
standards
ISO 6858, PN – ISO 461, DSF 400, ARP 5015
operating temperature range
-20°C ÷ +50°C
relative air humidity
up to 85%
protection rating
IP21

PARAMETERS
dimensions (L x W x H)
621 mm x 234 mm x 400 mm
weight
26 kg

Load Bank 3x200 V 400 Hz LO -115/260 type

With Load Bank LO-115/260 current loads can be set for 3x200 V, 400 Hz output voltage of a ground power unit for aircraft ground support equipment (GSE).

Features:

  • indication of the A, B and C live phases and of their rotation direction
  • load current setting by operator
  • testing ground power units by variable load current’s automatic setting according to a pre-defined programme
  • exhaust systems’ decarbonisation of GPU’s Diesel engine by variable load current’s automatic setting
  • according to a pre-defined programme
  • three-phase voltage, frequency, and current measurements with analogue indicators on the control panel
  • control and indication of EF protection system’s performance
  • connections to external control and measurement devices’ measuring sockets

The Load Bank provides comfort and functionality for everyday and scheduled maintenance of the power units. Its small weight and size allow easy loading and fixing in the service vehicle’s luggage compartment, significantly increasing the safety during transport.

Download PDF

Technical data

voltage / frequency
115 / 200 V a.c. ±10% / 400 Hz ±10%
power [kW / kVA cosɸ = 1]
0 – 90 kW ±10%
power adjustment
15 steps of 6 kW
load current measuring range
0-300 A a.c., accuracy grade 1.5
loaded voltage frequency measuring range
360/440 Hz, accuracy grade 1.5
voltage measuring range
0-250 V a.c., accuracy grade 1.5
GPU test programme
load power increase 0 - 100% [30s] constant
load power 100% [5min]
load power decrease 100 - 0% [10 min]
GPU Diesel engine decarbonisation
programme
load power increase 0 - 100% [30s] constant
load power 100% [45min]
load power decrease 100 - 0% [10 min]
operating temperature range
-20°C ÷ +50°C
ambient air relative humidity
up to 85%
protection rating
IP21
standards
ISO 6858, PN – ISO 461, DSF 400, ARP 5015

PARAMETERS
dimensions (L x W x H)
620 mm x 235 mm x 660 mm
weight
26 kg