Airfield Nitrogen Gasifier LGA/N

Airfield nitrogen gasifier LGA/N is designed for gasification of liquid nitrogen for filing dispenser cylinders and external cryogenic tanks with liquid nitrogen. LGA/N is mounted on a low chasiss and fit for towing. It is suitable for air transport.

LGA/N is powered from TN-C or TN-S three-phases a.c. mains or a power generator with the following parameters:

  • rated voltage 3 x 230 V / 400 V
  • frequency 50 Hz
  • power consumption at gasification, max. 40 kVA

Download PDF

Technical data

gas type
liquefied nitrogen, PN-C-84911 standard compliant
product name
gaseous nitrogen, PN-91 / L-01262 standard compliant
liquid nitrogen tank capacity
427 dm³
operating pressure in tank
max. 1,4 MPa
operating pressure in nitrogen system
max. 35 MPa
portable tank filing pressure
max. 1,4 MPa
discharged nitrogen „dew point” at pressure
0,1 MPa
no more than -55°C
capacity (at pressure gas discharge pressure 35 MPa and ambient temperature +20°C)
125 Nm³/h
max. discharged nitrogen temperature
+70°C
filtering accuracy
5 μm

PARAMETERS
dimensions with tow rod (L x W x H)
5900 mm x 1760 mm x 1585 mm
dimensions without tow rod (L x W x H)
4000 mm x 1760 mm x 1585 mm
weight with full liquid nitrogen tank
2850 kg
transport weight with empty tank
2505 kg

Airfield Oxygen Gasifier LGT/N

Airfield oxygen gasifier LGT/N is designed for liquid oxygen gasification for filing dispenser cylinders and external cryogenic tanks with liquid oxygen. LGT/N is mounted on a low chassis and fit for towing. It is suitable for air transport.

LGT/N is powered from TN-C or TN-S three-phases a.c. mains or a power generator with the following parameters:

  • rated voltage 3 x 230 V / 400 V
  • frequency 50 Hz
  • power consumption at gasification, max. 40 kVA

Download PDF

Technical data

gas type
liquefied oxygen, PN-C-84911 standard compliant
product name
oxygen gas, PN-93 / L-01267 standard compliant
liquid oxygen tank capacity
427 dm³
operating pressure in tank
max. 1,4 MPa
operating pressure in oxygen system
max. 16,5 MPa
gas cylinder (dispenser) filling pressure
15 MPa
discharged oxygen „dew point” at pressure 0,1 MPa
no more than -55°C
capacity (gas discharge pressure 15 MPa and ambient temperature +20°C)
min. 125 Nm³/h
portable cylinder with liquid oxygen filing pressure
no more than 1,4 MPa
max. discharged oxygen temperature
+70°C
filtering accuracy
5 μm

PARAMETERS
dimensions with tow rod (L x W x H)
5900 mm x 1760 mm x 1580 mm
dimensions without tow rod (L x W x H)
4000 mm x 1760 mm x 1580 mm
weight with full liquid oxygen tank
2650 kg
transport weight with empty tank
2200 kg