Ground Support Equipment
Ground power units
POWER GENERATOR ON TRAILER APP – 80/50
- generates electricity by converting energy from the internal combustion engine
- independent of other energy sources
- no external power source required
- source of electricity in the absence of an available power connection or in the event of a power outage in the power grid
- it can be transported by rail, water, car and air
Technical data
POWER SOURCE PARAMETERS
3-phase rated voltage
3x400/230V
rated current
115A
rated frequency
50Hz
power COP rating
64/80 kW/kVA
ENGINE TECHNICAL PARAMETERS
engine type
diesel, 4 cylinders
RICARDO R4105BZLDS
stabilization of rotational speed
1500 rpm
power
72 kW
weight
445 kg
PARAMETERS
dimensions (L x W x H)
4100 mm x 1900 mm x 1930 mm
weight
2000 kg
GPU-7/90 TAURUS
Ground power unit GPU-7/90 TAURUS is designed for a.c. and d.c. powering of an aircraft. It is driven by a multi-fuel engine and fit for towing.
GPU-7/90 TAURUS is equipped with the following systems:
- auto diagnostics,
- remote online diagnostics,
- keyless start,
- winter quick start,
- protection against towing with unwound outgoing cables,
- turbocharger protection against overheating,
- tire protection against punctures.
The unit is adapted for air transport.
Technical data
TECHNICAL DATA FOR A.C.
rated a.c. voltage
115 V/200 V, 400 Hz, 3 - phases, 4 - wires
continuous a.c. power
90 kVA with inductive power factor 0.8-1.0
voltage control range
112 V ÷ 118 V
rated phase current
260 A
max. phase current
290 A
TECHNICAL DATA FOR D.C.
rated voltage
28 V
voltage control range
26 V ÷ 29 V
rated current
800 A
max. current (in 30 secs. / in 1 sec)
1800 A/2500 A
PARAMETERS
dimensions (L x W x H)
3400 mm x 1500 mm x 1720 mm
weight
2260 kg
outgoing cables length
10 m
Ground Power Unit GPU 2/90 TAURUS eco
GPU 2/90 TAURUS eco is designed for a.c. powering of all types of aircraft. Mounting options for free standing, boarding bridges and rafter mount in hangars.
Equipment options:
- auto diagnostics
- automatic cable retriever
- remote control system (tablet as control panel)
- remote monitoring by Ethernet, CAN or Modbus
Technical data
Input
Nominal input voltage
3x400V/PE-50Hz
Maximum input voltage variations
+ 15% to -15%
Power factor
> 0.99 @ 50% - 100% load
Current distortion
<7% @ 100% load
Efficiency
> 90% @ 100% load
Output
Nominal output voltage
3x200V/400Hz + N
Nominal output power
90kVA
Voltage regulation
112-118V
Maximum output (phase) voltage on supply terminals
131V
PARAMETERS
dimensions (L x W x H)
600x600x1200 mm
weight
308 kg
Cable input
From the bottom